Powerstar Electric Tankless Water Heater
The OWNER and not the Manufacturer or his representative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the owner in order to repair the product. RP1P, RP2P, RP3P, RP7P, RP9P. Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect in the water heater component part(s) or from its use. When returning the water heater or component part(s), they must be individually tagged and identified with the Returned Goods Authorization # issued by Bosch Water Heating and shipped prepaid to Bosch Water Heating at the address below. YOU GET WHAT YOU SEE IN PICTURES. APPLIED ENERGY PRODUCTS THROUGH ITS U. S. Powerstar electric tankless water heater 45-550301. DISTRIBUTOR BOSCH WATER HEATING (herein after BBT) guarantees this water heater to the original owner of the water heater at the original installation location against defects in material and workmanship for the periods specified below. What's Included: AE115 Whole House Electric Tankless Water Heater - AE115. Ideal for homes as well as employee breakrooms, public restrooms, janitor closets, salons, medical facilities, veterinary offices and anywhere else you need hot water directly at the point-of-use. Whenever I have to fix any of these high tech plumbing gadgets for the first time, I google up the manual and read about it.
- Powerstar electric tankless water heater 45-557701
- Powerstar electric tankless water heater 110v
- Powerstar electric tankless water heater ae9.5
- Powerstar electric tankless water heater 45-552703
- Powerstar electric tankless water heater repair
- Powerstar electric tankless water heater 45-550301
- Powerstar electric tankless water heater model 45-552703
Powerstar Electric Tankless Water Heater 45-557701
Works in all electric markets. Results 1 to 12 of 12. Weird way for such a large company to operate. Its easily removed and cleaned. In Canada the unit has just one voltage supply). Powerstar electric tankless water heater ae9.5. I then asked him for the proper way to interpret the nomenclature for their electric tankless water heaters. Is there any hope, or is this a POS than needs replaced/upgraded? Disconnect this product from the elec trical supply before cleaning, servicing or removing the cover.
Powerstar Electric Tankless Water Heater 110V
This is good for washing hands but not much else. Yeah, I know, I know that's waaaaaay too long. Myrtle Beach, S. C. ). Any Component Part Other Than The Heat Exchanger- If any other component part (other than the heat exchanger) proves to be defective in material or workmanship within one (1) year from the date of original installation of the water heater, Bosch Water Heating will furnish the Owner with a replacement of the defective part(s). It seems like there must be a problem with flow rate issue. POWERSTAR AE95 Bosch PowerStar AE9.5 Point-of-Use Electric Tankless Water Heater. 5 Electric Tankless Water Heater. Tronic 5000C Electric Tankless. F. (6) offer up reviews. Message (required): Send Message Cancel. In reply to tr8todd: It has separate hot & cold valves, so that confirms its in the unit. If the 8 which follows the D represents the week (the 8th week would be February) then it would need two digits to represent March, April, May, June,... etc. If the input voltage is less than 240 then the wattage will be reduced thus the output temperatures will be reduced. She holds a Bachelor of Arts in history from San Francisco State University.
Powerstar Electric Tankless Water Heater Ae9.5
Notice the dummy that typed the instructions says the digits represent the month and year when he means to say they represent the year first and then the month, sheesh. 90% efficiency rating. Reset or replace the fuse or circuit breaker if needed. Cleaning/Descaling Electric Tankless Water Heater. This one is a few years old, so that could be a possibility. However, we are finding that some of the merchandise has actually been stolen from our customers.
Powerstar Electric Tankless Water Heater 45-552703
I am having a [40 foot canoe] and is ideal for household needs. Elster American Meter. PowerStar point-of-use tankless water heaters are designed to provide an endless supply of hot water for kitchen bathroom and hand-washing sinks. How to Troubleshoot a PowerStar Electric On Demand Water Heater | HomeSteady. Manufacturer shall not be liable under this warranty if: - The water heater or any of its component parts has been subject to misuse, alteration, neglect or accident, or; - The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) and/or regulation(s), or; - The water heater has not been installed in accordance with the printed manufacturer's instructions, or; - The water heater is not continuously supplied with potable water. …at the outlet side? That part was replaced under warranty.
Powerstar Electric Tankless Water Heater Repair
Also, if the faucets are older ones with washers, the washers can swell with the hot water causing the flow to be reduced until the reach the same temp as the water. Features solid copper heat exchanger copper-sheathed elements and tough plastic housing. How the Owner can secure service or make a claim. Powerstar electric tankless water heater 110v. This unit may still not be "big" enough for cold weather climates if the inlet temperatures are 50 thus the outlet temperature would be 90. Any help would be appreciated. Close the access panel and restore power. Make sure that the ground wire is wrapped around its terminal stud and into the saddle washer. Note: The unit will work at lower supply voltages but the following changes Maximum output Temperature control range Maximum flow rate (refer to Graph 1, Page 8) WARNING Always switch off the electricity supply to the unit before you remove the cover. Can you adjust the temperature output on your unit or is it controlled externally by a tempering valve?
Powerstar Electric Tankless Water Heater 45-550301
Powerstar Electric Tankless Water Heater Model 45-552703
Further, we reserve the right to require a legitimate sales receipt showing that the product was purchased from one of our customers in order to provide warranty coverage. Mounts on wall in any direction and is space saving, ultra-compact, and lightweight. Nothing in there indicates February (the second month)... unless that is what the D represents, but D if the fourth letter....??? Again I had to pay electrician to install that part. To operate correctly, the unit needs the following running pressures: Minimum: 15 psi (1 Bar) Securing the unit to the wall Diagram 1 IMPORTANT Read entire instructions. Important Safety Instructions When using this electrical equipment, basic safety precautions should always be followed, including the following: 1. Adjust hot and/or cold taps to prevent bodily harm. I had this model tankless water heater installed in my home in 2008. But I thought that had more to do with demand than temp regulation.... Rant - Mine will shut off if I am not using a significant amount of hot, like when shaving.
We believe that in some cases there are legitimate consumers trying to sell product that they have purchased through legitimate distribution channels. Eliminates long waits for hot water. After another long pause he responded; I don't really know. The heaters are rated based on a full 240 volts. The Heat Exchanger - If the original heat exchanger leaks within ten (10) years from the date of original installation of the water heater, because of a defect in material or workmanship, Bosch Water Heating will furnish to such Owner a new heater of the then prevailing comparable model. Turn the thermostat knob to a higher setting if the water is cold and the neon indicator light is on. None of these heaters comes with a plug so they need to be HARD WIRED back to an electrical panel due to their amperage requirements. Controlled Energy Corporation (CEC) is. Provides an ENDLESS supply of hot water. This is NOT a linear function. Owner should contact the dealer who sold the water heater covered by this warranty or. These heaters are built to last, save valuable floor space and mount easily on the wall. At a flow rate of 1 gpm, the unit will provide about a 45 degree change in the water temperature.
That day one of the elements in the heater exploded (destroying the unit completely and heavily damaging the bathroom along with it. Most of these units now have an error code screen that narrows down the search for you, but those usually only flash once a shut down occurs. Sounds like the problem can be in the shower valve. I'm going to install our old shower head from the last place & see if that makes a difference. CEC Products: ||Bosch AquaStar tankless gas water heaters provide anendless supply of. Three 40 amp breakers/200 amp electric service required. Turn off and unplug the water heater if there is only cold water. The way its suppose to work goes like this. We're sorry, but this item is no longer available.
I then disconnected the hose that ran from the pump INTO the water heater and tested the pump (I plugged the pump in and just routed the pump's hose so it returned the vinegar solution directly back into the bucket/totally bypassing the water heater) and the pump ran fine; put out probably 5 gallons a minute so the pump itself is good. If being used in a public place, position the unit out of easy reach to discourage vandalism. Installation Manual (multi-lingual). After some diagnostic testing with an electrician (that I once again had to pay) Bosch informed us that the motherboard to the unit had gone bad.